Induction Acorn Light Fixtures| 90xxx Series Description
|
Ballast Type
Start Method
Hot Re-start
Universal Input Line Voltage
Input Line Frequency
Lamp/Ballast System Life
Lumen Maintenance @75,000Hrs
Color Temperature
Color Rendering Index (CRI)
|
Electronic InstantON InstantON 120-277 VAC 50/60 Hz 100,000 Hrs. >70% 5000 K 83 |
Minimum Starting Temperature
Maximum Operating Temperature
Lamp Operating Frequency
Power Factor
Total Harmonic Distortion
Inrush Current Peak
ETL Listed / UL Standard 1598
FCC Compliance
|
-20 F 160 F 250 kHz > 0.98 < 10% < 10 Amp Yes Part 18, Subp. C |
Induction Acorn Light Fixtures| 90xxx Series
Application, Features and Benefits
- Dark Sky Friendly - Full Cut-OFF
- Heat and UV resistant non-yellowing polycarbonate lens
- Die-cast aluminum housing with electrocoat black paint
- Ballast made with long life components
- InstantON(TM) flicker-free Cold Start and Hot Re-Start
- Correlated Color Temperature of 5000° K for greater visibility
- High Power Factor, Low THD Replaceable Ballast
- Concealed continuous gasket seals against harmful dust, dirt, moisture and insects
- Advanced phosphors for high Lumen Maintenance and high lumen output
- 3" Inside Diameter Slip Fitter to accept 2-7/8" O.D. Tenon or Pole
- Up to 20 years Maintenance free operation
Product Information
| 90050 |
Acorn Fixture |
|
3,500 |
120-277 VAC |
0.46-0.25 Amp |
<30% |
0.98 |
18.0 in. 457 mm |
18.0 in. 457 mm |
36.0 in. 914 mm |
Voltage: (UNV) = 120V / 208V / 277V