Induction 16" Square Flood Light Fixtures - 38xxx Series Description

  • Ballast Type
  • Start Method
  • Hot Re-start
  • Universal Input Line Voltage
  • Input Line Frequency
  • Lamp/Ballast System Life
  • Lumen Maintenance @75,000Hrs
  • Color Temperature
  • Color Rendering Index (CRI)
  • Electronic
    InstantON
    InstantON
    120-277 VAC
    50/60 Hz
    100,000 Hrs.
    >70%
    5000 K
    83
  • Minimum Starting Temperature
  • Maximum Operating Temperature
  • Lamp Operating Frequency
  • Power Factor
  • Total Harmonic Distortion
  • Inrush Current Peak
  • ETL Listed / UL Standard 1598 
  • FCC Compliance
  • -20 F
    160 F
    250 kHz
    > 0.98
    < 10%
    < 10 Amp
    Yes
    Part 18, Subp. C

    Induction 16" Square Flood Light Fixtures - 38xxx Series

    Application, Features and Benefits

    Product Information

    Item No. Description Watts Initial
    Lumens
    Line
    Voltage
    Supply
    Line Current Total
    Harmonic
    Distortion
    (THD)
    Power Factor Packaging Dimensions
    Width Length Height
    38080 16” FLOOD Fixture 80 6,400 120-277 VAC 0.69-0.30 Amp <10% 0.98 18in. 460mm 18in. 460mm 15in. 380mm
    38100 16” FLOOD Fixture 100 8,000 120-277 VAC 0.87-0.37 Amp <10% 0.98 18in. 460mm 18 in. 460mm 15in. 380mm
    38120  16" FLOOD Fixture 120 9,600 120-277 VAC 1.05-0.45 Amp <10% 0.98 18in. 460mm 18in. 460mm 15in. 380mm
    38150 16” FLOOD Fixture 150 12,000 120-277 VAC 1.31-0.56 Amp <10% 0.98 18in. 460mm 18in. 460mm 15in. 380mm
    38200 16” FLOOD Fixture 200 16,000 120-277 VAC 1.75-0.75 Amp <10% 0.98 18in. 460mm 18in. 460mm 15in. 380mm

    Voltage: UNV = 120V-277V [ Higher 347V or 480V ]
    Mounting Options: -SF (Slip Fitter) or -YK (Yoke Bracket)